2 min readBiohybrid

Current or light: the two ways to tell living muscle in a robot when to contract

Biohybrid robots are driven by real muscle tissue. Controlling that tissue is mostly a choice between electrodes and optogenetics.

A biohybrid robot uses living muscle as its actuator. The tissue is grown from cells on a scaffold, then attached to a synthetic skeleton. Getting it to contract on command is the control problem. It has two main answers.

Electrical stimulation

Muscle cells contract when the voltage across their membranes changes. Put electrodes near the tissue, pulse a field and it twitches. This works on unmodified cells and needs nothing more than a pulse generator. The drawbacks are selectivity and side effects. A field reaches every cell nearby, so separate muscles are hard to drive independently. Electrodes in salty culture medium can also split water and release by-products that damage the tissue over time.

Optogenetics

Optogenetics edits the cells so that they carry a light-sensitive ion channel, most commonly channelrhodopsin-2. A pulse of blue light then opens the channel and the cell fires. Only the engineered cells respond, so two muscles side by side can be driven separately with two lights. The light sources can be tiny LEDs mounted on the robot itself.

The most advanced example so far comes from Northwestern University and the University of Illinois. In a paper in Science Robotics in September 2025, Hyegi Min and colleagues in the groups of John Rogers, Yonggang Huang and Rashid Bashir built a crawling robot in which light did not act on the muscle directly. It acted on optogenetically modified motor neurons, which then drove the muscle through real neuromuscular junctions, as in an animal. Wireless micro-LEDs on board delivered the pulses. The robots stayed mechanically functional for more than two weeks. Strikingly, the muscle kept contracting for up to 20 minutes after a single one-minute burst of light at 2 Hz. The authors suggest the neurons were tuning the muscle's output, not just relaying a signal.

Optical control is also what MIT used in its recent work on hydrogel tendons.

Why a PAM blog cares

Living muscle is, in a sense, the end-point of soft actuation. It is self-assembling, self-repairing and fuelled by sugar. It is nowhere near ready to compete. Forces are tiny, lifetimes are short and the tissue has to be kept warm and fed. But the control methods being worked out now, such as selective wireless activation of many small actuators, apply to synthetic muscles too. A pneumatic-muscle array with one valve per muscle faces the same addressing problem as a sheet of light-driven muscle with one LED per bundle.